5ton 3ton Used Toyota Fd30 Fd50 Forklift with Overhaul Maintenance
2. Static test oil motive cannot be fully opened or fully closed.
3. steam turbine speed or electricity and heat load fluctuations.
4. Extraction and back pressure cannot be put into operation.
Our company adheres to the business philosophy of 'responsibility wins respect, innovation wins competition', abides by the principle of honesty and mutual benefit, and contributes to the industry of Circulating Fluidized Bed Steam Boiler, Water Wall Tube Panel, Bagasse Boiler. The development of the enterprise needs the simultaneous development of talents. If we do not actively learn and progress, we may not be able to keep up with the development of the enterprise, and only by continuous learning and continuous progress can we add value to the enterprise continuously, which is the talent we are most eager for. With a high sense of political responsibility, mission and commitment, we actively return the fruits of development to society. Accurate grasp of the market trends is our main concern, as it is the most powerful means to improve our competitiveness.
Speed regulation and security system Faults:
1. Increase or decrease load is insensitive, there is a jump change.
2. Static test oil motive cannot be fully opened or fully closed.
3. steam turbine speed or electricity and heat load fluctuations.
4. Extraction and back pressure cannot be put into operation.
5. Regulating valve seal is lax.
6. Steam leakage of valve stem.
7. The emergency breaking throttle, axial displacement breaking device, starting valve, emergency breaking and resetting device cannot hang the brake.
8. Additional security oil pressure and safety oil pressure cannot be established or the oil pressure is low.
9. Low speed emergency interrupt throttle, security operation box.
10. The oil injection test was unsuccessful.
11. LVDT calibration of turbine oil motive.
12. Configuration setting of WoodWard505, 505E, SPC and CPCⅡ ⅱ parameters.
13. The pulse oil pressure (signal oil pressure) of hydraulic spring-type oil motor cannot be established or is lower than the design value.
14. Oil motive shut down for too long.
15. OPC function cannot be put into use.
16. The rotary slide valve cannot rotate.
17. Can't run at full capacity.
18. Steam turbine load rejection speed soaring is too large.
19. Unequal rate adjustment of speed control system.
Main valve
1. When hot, the main valve can't be seated.
2. After the main valve is opened to a certain extent, it will automatically close.
3. The main valve cannot be opened.
4. The main valve does not open properly.
5. Large steam leakage.
6. The automatic shutoff cannot be tested for activities.
7. The opening of the automatic shutter is not in place.
8. The closing time of the main valve/automatic shutoff is too long
Oil system
1. The pressure of high-pressure oil pump is less than the design value.
2. The outlet pressure/inlet pressure of main oil pump of steam turbine is insufficient.
3. Insufficient pressure of turbine lubricating oil.
4. The oil return temperature of steam turbine is too high.
5. The outlet temperature of oil cooler is too high.
6. Insufficient outlet pressure of lubricating oil pump.
7. The three-way non-return valve is jammed.
8. The output of high-pressure oil pump does not match the system.
9. Poor oil return
10. Oil leakage of bearing seat
Our 5ton 3ton Used Toyota Fd30 Fd50 Forklift with Overhaul Maintenance have been widely praised for their high reliability, high efficiency and high stability. We promote the healthy development of the industry market, create value for society, and contribute to national construction. With the aggravation of market competition, the industry is facing the severe test of frequent changes in order tasks and shorter delivery time.