Extraction Condensing Steam Turbine for Power Plant EPC

Extraction Condensing Steam Turbine for Power Plant EPC

The stator is composed of a base, a stator core and a stator winding.
The frame is welded by steel plates, the structure is light and strong, and the frame is divided into many air inlet and outlet areas along the axial direction;
Send Inquiry
Product Introduction

We always get the job done to be a tangible staff to ensure that we can easily offer you the best high-quality and the greatest value for Biomass Boiler, Air Preheater, Steam Turbine Diaphragm. We are committed to becoming a learning organization where each person is fully engaged and experiences the meaning of life at work. We always pay attention to the working environment of our employees and take preventive measures for different positions to ensure the safety and health of our employees. From customization to production to after-sales service, the whole process of our company is all made by professionals, and we are bound to take customers' needs as our purpose. We pursue the development concept and consciousness of speed and efficiency, competing with speed and winning with speed.

Product Overview

1. Local characteristics and performance analysis

● Stator:

The stator is composed of a base, a stator core and a stator winding.

The frame is welded by steel plates, the structure is light and strong, and the frame is divided into many air inlet and outlet areas along the axial direction;

Stator coil:

It is made of multiple strands of polyester fiberglass-covered copper wire, and adopts a semi-group blue structure (some adopts transposition structure); the insulation grade of the coil is F grade, and the mica tape is continuously wrapped and molded. The end of the coil is made of weftless tape or The polyester glass rope is tied tightly with the bracket and the binding ring, so that the unit has a high tolerance to sudden short circuits.

Stator core:

The stator core is made of cold-rolled non-oriented, high-permeability, low-loss, high-quality silicon steel sheets that are punched and laminated. Both sides of the silicon steel sheets are coated with a strong insulating paint film to prevent short circuits between the stator core sheets and reduce eddy current loss.

Generator rotor:

The rotor is composed of a rotating shaft, a coil, a center ring, a guard ring, a fan ring, etc. The rotor coil is wound by cold-drawn flat copper wire and subjected to oxygen-free annealing. The rotor coils of 50MW and above steam turbine generators are tailor-welded with silver-containing cold drawn copper wires, and are insulated with class F.

The guard ring located at the end of the rotor coil is made of non-magnetic steel. Both ends of the rotor are equipped with centrifugal fans or axial fans with blades forged from high-strength aluminum alloy.

Rotor processing:

The rotating shaft of the generator is forged from a whole high-quality alloy steel. Axial slot is machined on it to embed the rotor coil, and the large teeth are provided with ventilation slots or crescent slots to enhance the cooling of the body and coil ends. , It adopts the special CNC milling machine for the rotor of Italian tower base generator to ensure the efficiency of the generator.

The generator rotor must undergo high-speed dynamic balance experiment and dynamic variable current impedance experiment before leaving the factory to test the mechanical strength of the rotor and ensure excellent inter-turn insulation of the rotor winding.


2. Cooling method

The steam turbine generator adopts closed air self-circulation ventilation method.

Turbine generator rotors below 50MW adopt indirect ventilation cooling;

The rotor of 50MW and above steam turbine generator adopts direct ventilation and cooling. The rotor winding slot is milled with auxiliary slots, and the rotor winding is milled with ventilation holes. Under the action of the fan head and the centrifugal pressure head of the rotor winding vent, the cold air passes through Secondary slots and ventilation holes directly cool the rotor windings.


3. Excitation method

The turbine generator produced can adopt three excitation methods: static thyristor, two-unit AC brushless excitation and three-unit AC brushless excitation.


4. Insulation system

It adopts F-class insulation material and insulation structure, and is evaluated according to the B-class insulation level during operation, and a certain degree is reserved.


5. Design and acceptance criteria

The design, production, and acceptance are carried out in accordance with the latest standards of relevant countries, and at the same time meet the requirements of the latest standards of the International Electrotechnical Commission IEC34-1. According to customer requirements, the turbine generators produced can also be designed, manufactured and inspected in accordance with ANSI, NEMA and other international standards.


Main Specifications

Turbo-Generator Ratings

Model

Capacity (KVA)

Rated power (v)

Voltage (v)

Current (A)

Power factor cosф

Efficiency (%)

Rated speed (r/min)

TQTK0.75-4

937.5

750

400

1355

0.8

93.0

1500

QFK-1.5-2

1875

1500

6300

172

0.8

94.5

3000

10500

103

QFK-3-2

3750

3000

6300

344

0.8

95.3

3000


10500

206

QF-3-2

3750

3000

6300

344

0.8

95.3

3000

10500

206

QF-4.5-2

5625

4500

6300

515


0.8

95.3

3000

10500

309

QF-6-2

7500

6000

6300

688

0.8

96.4

3000

10500

412

QF-7.5-2

9375

7500

6300

859

0.8

96.4

3000

10500

515

QF-12-2

15000

12000

6300

1375

0.8

97

3000

10500

825

QF-15-2

18750

15000

6300

1718

0.8

97

3000

10500

1031


Turbo-Generator Ratings above 25MW


model

capacity
(KVA)

rated power
(kW)

rated voltage
(V)

rated current
(A)

power factor
cosφ

efficiency
(%)

rated speed
(r/min)

QF-K25-2

31250

25000

6300

2863

0.8

97.8

3000

10500

1718

97.61

QF-K30-2

37500

30000

6300

3436

0.8

97.93

3000

10500

2062

97.8

QF-K50-2

62500

50000

6300

5728

0.8

98.4

3000

10500

3436

98.3

QF-K60-2

75000

60000

6300

6873

0.8

98.49

3000

10500

4124

98.41

QF-K135-2

158823

135000

13800

6644

0.8

98.4

3000


We try our best to reduce the cost of our Extraction Condensing Steam Turbine for Power Plant EPC and provide our customers with the best quality and inexpensive products as well as considerate services to win the market and create the future together with our customers. We hope that every employee should have a sense of collective honor and give full play to the team spirit. We have the courage to explore, dare to innovate business philosophy and innovative thinking, good planning and practical work, and constantly climbing the spirit of the times.

Send Inquiry

whatsapp

Phone

E-mail

Inquiry