Power Station Overhaul and Maintenance

Power Station Overhaul and Maintenance

1. Increase or decrease load is insensitive, there is a jump change.
2. Static test oil motive cannot be fully opened or fully closed.
3. steam turbine speed or electricity and heat load fluctuations.
4. Extraction and back pressure cannot be put into operation.
Send Inquiry
Product Introduction

We promote Boiler Parts, Bleed Back Pressure Type, Organic Rankine Cycle (ORC) Solution optimization and upgrading, produce high-performance, high-value-added products, and drive energy conservation and emission reduction in the industry. We will establish a fair, open and flexible platform for the growth and advancement of employees by continuously improving the employment and distribution mechanism, giving opportunities to those who want to work, giving positions to those who can work, and giving status to those who have done a good job. Our company will adhere to the business philosophy of taking technology as the guide, quality as the core, and quality as the service. Guests and friends from all walks of life are welcome to visit and guide! We firmly believe that we will do better!

Speed regulation and security system Faults:

1. Increase or decrease load is insensitive, there is a jump change.

2. Static test oil motive cannot be fully opened or fully closed.

3. steam turbine speed or electricity and heat load fluctuations.

4. Extraction and back pressure cannot be put into operation.

5. Regulating valve seal is lax.

6. Steam leakage of valve stem.

7. The emergency breaking throttle, axial displacement breaking device, starting valve, emergency breaking and resetting device cannot hang the brake.

8. Additional security oil pressure and safety oil pressure cannot be established or the oil pressure is low.

9. Low speed emergency interrupt throttle, security operation box.

10. The oil injection test was unsuccessful.

11. LVDT calibration of turbine oil motive.

12. Configuration setting of WoodWard505, 505E, SPC and CPCⅡ ⅱ parameters.

13. The pulse oil pressure (signal oil pressure) of hydraulic spring-type oil motor cannot be established or is lower than the design value.

14. Oil motive shut down for too long.

15. OPC function cannot be put into use.

16. The rotary slide valve cannot rotate.

17. Can't run at full capacity.

18. Steam turbine load rejection speed soaring is too large.

19. Unequal rate adjustment of speed control system.


Main valve

1. When hot, the main valve can't be seated.

2. After the main valve is opened to a certain extent, it will automatically close.

3. The main valve cannot be opened.

4. The main valve does not open properly.

5. Large steam leakage.

6. The automatic shutoff cannot be tested for activities.

7. The opening of the automatic shutter is not in place.

8. The closing time of the main valve/automatic shutoff is too long


Oil system

1. The pressure of high-pressure oil pump is less than the design value.

2. The outlet pressure/inlet pressure of main oil pump of steam turbine is insufficient.

3. Insufficient pressure of turbine lubricating oil.

4. The oil return temperature of steam turbine is too high.

5. The outlet temperature of oil cooler is too high.

6. Insufficient outlet pressure of lubricating oil pump.

7. The three-way non-return valve is jammed.

8. The output of high-pressure oil pump does not match the system.

9. Poor oil return

10. Oil leakage of bearing seat


We always adhere to the concept of comfortable, practical, changeable appearance and multiple choices in development, R&D and production of our Power Station Overhaul and Maintenance. In response to the complex and severe domestic and international economic situation, we carry forward the spirit of hard work and innovation. We sincerely provide good products and good service for our customers, and warmly welcome new and old customers to establish long-term and stable cooperative relationship with our factory and create a brilliant tomorrow together.